The product group has been withdrawn from production.
Suggested replacement: JV205 and JV305 JOHNSON CONTROLS ball valves
Product selection table
Factory fitted valve assemblies with PROPORTIONAL actuators
Valve codes * | Cor- pus |
Kvs (Harbor main) |
Kvs (Harbor bypass) ** |
Shield character ristics |
Acceptable combinations of valves, connecting systems and actuators | |||||||
Spring return function | — | • | ||||||||||
Supply voltage | 24 VAC | |||||||||||
Torque | 4Nm | 8Nm | 6Nm | 16Nm | ||||||||
Run time | 72 s | 30 s | 25 - 40 s | 90-120 p | ||||||||
Running time - spring return | — | 35 s (max 70 s) | 10 s | |||||||||
VDC control signal | 0-10/2-10 | |||||||||||
MA control signal | 0-20/4-20 | — | ||||||||||
Switches | — | 2 x SPDT | — | 1xSPDT | — | 2xSPDT | ||||||
VDC feedback | — | 0-10/2-10 | 0-10 | |||||||||
Closing pressure | 1380 kPa | |||||||||||
Actuator codes | BMD1.2 | BMD1.2c | BMS1.1 | BMS1.1S | DMF1.06 | DMF1.06S | DMF1.1F | DMF1.1FS | ||||
Liaison system codes | — | ZAK2 | ZAK3 | ZAK4 | ||||||||
Code that must be added to the valve code to order a valve with an actuator fitted | + BMD1.2 | + BMD1.2C | + BMS1.1 | + BMS1.1S | + DMF106 | + DMF106S | + DM1.1F | + DM1.1FS | ||||
JVx05AD | DN15 | 1,0 | 0,63 | • | • | • | • | • | • | • | — | — |
JVx05AE | 1,6 | 1,0 | • | • | • | • | • | • | — | — | ||
JVx05AF | 2,5 | 1,6 | • | • | • | • | • | • | — | — | ||
JVx05AG | 4,0 | 2,5 | • | • | • | • | • | • | — | — | ||
JVx05AL | 6,3 | 4,0 | • | • | • | • | • | • | — | — | ||
JVx05AN | 10 | 5,0 | — | • | • | • | • | • | • | — | — | |
JVx05BL | DN20 | 6,3 | 4,0 | • | • | • | • | • | • | • | — | — |
JVx05BN | 10 | 5,0 | — | • | • | • | • | • | • | — | — | |
JVx05CN | DN25 | 10 | 6,3 | • | • | • | • | • | • | • | — | — |
JVx05CP | 16 | 8 | — | • | • | • | • | • | • | — | — | |
JVx05DP | DN32 | 16 | 10 | • | — | — | • | • | • | • | — | — |
JVx05DR | 25 | 12,5 | — | — | — | • | • | • | • | — | — | |
JVx05ER | DN40 | 25 | 16 | • | — | — | • | • | • | • | — | — |
JVx05ES | 40 | 20 | — | — | — | • | • | • | • | — | — | |
JVx05FS | DN50 | 40 | 25 | • | — | — | • | • | — | — | • | • |
JVx05FT | 63 | 21,5 | — | — | — | • | • | — | — | • | • |
NOTE:
* x = 2-way
* x = 8 three-way
** x = 8 only three-way
Factory-fitted valve assemblies with THREE-POINT AND ON / OFF actuators.
Valve codes * | Cor- pus |
Kvs (Harbor main) |
Kvs (Harbor bypass) ** |
Shield character ristics |
Acceptable combinations of valves, connecting systems and actuators | |||||||||||
Spring return function | — | • | ||||||||||||||
Supply voltage | 24VAC | 230VAC | 24VAC | |||||||||||||
Torque | 4 Nm | 8 Nm | 6 Nm | 16 Nm | ||||||||||||
Run time | 72 s | 30 s | 60-90 p | 90-120 p | ||||||||||||
Running time - spring return | — | 35 s (max. 70 seconds) |
10 s | |||||||||||||
Control signal | three-point | three-point with switch and ON / OFF timer. |
three-point | |||||||||||||
Switches | — | 2xSPDT | — | 2xSPDT | — | 1xSPDT | — | 2xSPDT | ||||||||
VDC feedback | — | |||||||||||||||
Closing pressure | 1380 kPa | |||||||||||||||
Actuator codes | BAD1.4 | BAD1.4C | BAD1 | BAD1C | BAS1 | BAS1.S | BAS2 | BAS2.S | DBF1.06 | DBF1.06S | DAF1.4F | DAF1.4FS | ||||
Liaison system codes | — | ZAK2 | ZAK3 | ZAK4 | ||||||||||||
Code that must be added to the valve code to order a valve with an actuator fitted | + BAD1.4 | + BAD1.4C | + BAD1 | + BAD1C | + BAS1 | + BAS1.S | + BAS2 | + BAS2.S | + DBF106 | + DBF106S | + DAF1.4F | + DAF1.4FS | ||||
JVx05AD | DN15 | 1,0 | 0,63 | • | • | • | • | • | • | • | • | • | • | • | — | — |
JVx05AE | 1,6 | 1,0 | • | • | • | • | • | • | • | • | • | • | — | — | ||
JVx05AF | 2,5 | 1,6 | • | • | • | • | • | • | • | • | • | • | — | — | ||
JVx05AG | 4,0 | 2,5 | • | • | • | • | • | • | • | • | • | • | — | — | ||
JVx05AL | 6,3 | 4,0 | • | • | • | • | • | • | • | • | • | • | — | — | ||
JVx05AN | 10 | 5,0 | — | • | • | • | • | • | • | • | • | • | • | — | — | |
JVx05BL | DN20 | 6,3 | 4,0 | • | • | • | • | • | • | • | • | • | • | • | — | — |
JVx05BN | 10 | 5,0 | — | • | • | • | • | • | • | • | • | • | • | — | — | |
JVx05CN | DN25 | 10 | 6,3 | • | • | • | • | • | • | • | • | • | • | • | — | — |
JVx05CP | 16 | 8,0 | — | • | • | • | • | • | • | • | • | • | • | — | — | |
JVx05DP | DN32 | 16 | 10 | • | — | — | — | — | • | • | • | • | • | • | — | — |
JVx05DR | 25 | 12,5 | — | — | — | — | — | • | • | • | • | • | • | — | — | |
JVx05ER | DN40 | 25 | 16 | • | — | — | — | — | • | • | • | • | • | • | — | — |
JVx05ES | 40 | 20 | — | — | — | — | — | • | • | • | • | • | • | — | — | |
JVx05FS | DN50 | 40 | 25 | • | — | — | — | — | • | • | • | • | — | — | • | • |
JVx05FT | 63 | 31,5 | — | — | — | — | — | • | • | • | • | — | — | • | • |
NOTE:
* x = 2-way
* x = 8 three-way
** x = 8 only three-way
Factory fitted valve assemblies with ON / OFF actuators
Valve codes * | Cor- pus |
Kvs (Harbor main) |
Kvs (Harbor bypass) ** |
Shield character ristics |
Acceptable combinations of valves, connecting systems and actuators | |||||||
Spring return function | • | |||||||||||
Supply voltage | 24VAC | 230VAC | ||||||||||
Torque | 6 Nm | 16Nm | 6Nm | 16Nm | ||||||||
Run time | 10-40 p | 90-120s | 10-40 p | 90-120 p | ||||||||
Running time - spring return | 30 s ± 20% | 10 s | 30 s ± 20% | 10 s | ||||||||
Control signal | ON / OFF | |||||||||||
Switches | — | 1x SPDT | — | 2xSPDT | — | 1xSPDT | — | 2xSPDT | ||||
Feedback | — | |||||||||||
Closing pressure | 1380 kPa | |||||||||||
Actuator codes | DAF1.06 | DAF1.06S | DAF1.F | DAF1.FS | DAF2.06 | DAF2.06F | DA2.F | DA2.FS | ||||
Liaison system codes | ZAK3 | ZAK4 | ZAK3 | ZAK4 | ||||||||
Code that must be added to the valve code to order a valve with an actuator fitted | + DAF106 | + DAF106S | + DA1.F | + DA1.FS | + DAF.206 | + DAF206S | + DA2.F | + DA2.FS | ||||
JVx05AD | DN15 | 1,0 | 0,63 | • | • | • | — | — | • | • | — | — |
JVx05AE | 1,6 | 1,0 | • | • | — | — | • | • | — | — | ||
JVx05AF | 2,5 | 1,6 | • | • | — | — | • | • | — | — | ||
JVx05AG | 4,0 | 2,5 | • | • | — | — | • | • | — | — | ||
JVx05AL | 6,3 | 4,0 | • | • | — | — | • | • | — | — | ||
JVx05AN | 10 | 5,0 | — | • | • | — | — | • | • | — | — | |
JVx05BL | DN20 | 6,3 | 4,0 | • | • | • | — | — | • | • | — | — |
JVx05BN | 10 | 5,0 | — | • | • | — | — | • | • | — | — | |
JVx05CN | DN25 | 10 | 6,3 | • | • | • | — | — | • | • | — | — |
JVx05CP | 16 | 8,0 | — | • | • | — | — | • | • | — | — | |
JVx05DP | DN32 | 16 | 10 | • | • | • | — | — | • | • | — | — |
JVx05DR | 25 | 12,5 | — | • | • | — | — | • | • | — | — | |
JVx05ER | DN40 | 25 | 16 | • | • | • | — | — | • | • | — | — |
JVx05ES | 40 | 20 | — | • | • | — | — | • | • | — | — | |
JVx05FS | DN50 | 40 | 25 | • | — | — | • | • | — | — | • | • |
JVx05FT | 63 | 31,5 | — | — | — | • | • | — | — | • | • |
NOTE:
* x = 2-way
* x = 8 three-way
** x = 8 only three-way