Astra Automation > Products > Valves > Regulating valves > Schneider Electric SmartX PIBCV (VP22) balancing and control valves
Schneider Electric SmartX PIBCV (VP22) balancing and control valves

SmartX PIBCV (VP22) valves from Schneider Electric are a family of balancing and control valves that provide flow limitation with 100% authority over the entire flow range. Automatic function ...

SmartX PIBCV (VP22) valves from Schneider Electric are a family of balancing and control valves that provide flow limitation with 100% authority over the entire flow range. The automatic balancing function of the PIBCV valve ensures a stable refrigerant flow regardless of pressure changes in the system.


Product selection table
Model Description
VP228E-10BQLNT Balancing and control valve
- without measuring points
- PN16, DN10
- flow 30… 150 l / h
- thread connection. outside 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-15BQLNT Balancing and control valve
- without measuring points
- PN16, DN15
- flow 55… 275 l / h
- thread connection. outside 3/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-10BQSNT Balancing and control valve
- without measuring points
- PN16, DN10
- flow 55… 275 l / h
- thread connection. outside 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-15BQSNT Balancing and control valve
- without measuring points
- PN16, DN15
- flow 90… 450 l / h
- thread connection. outside 3/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-20BQSNT Balancing and control valve
- without measuring points
- PN16, DN20
- flow 180… 900 l / h
- thread connection. outside 1 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-25BQSNT Balancing and control valve
- without measuring points
- PN16, DN25
- flow 340… 1700 l / h
- thread connection. outside 1 1/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-32BQSNT Balancing and control valve
- without measuring points
- PN16, DN32
- flow 640… 3200 l / h
- thread connection. outside 1 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-15BQHNT Balancing and control valve
- without measuring points
- PN16, DN15
- flow 227… 1135 l / h
- thread connection. outside 3/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-20BQHNT Balancing and control valve
- without measuring points
- PN16, DN20
- flow 340… 1700 l / h
- thread connection. outside 1 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-25BQHNT Balancing and control valve
- without measuring points
- PN16, DN25
- flow 545… 2700 l / h
- thread connection. outside 1 1/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-32BQHNT Balancing and control valve
- without measuring points
- PN16, DN32
- flow 800… 4000 l / h
- thread connection. outside 1 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-10BQL Balancing and control valve
- with measuring points
- PN16, DN10
- flow 30… 150 l / h
- thread connection. outside 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-15BQL Balancing and control valve
- with measuring points
- PN16, DN15
- flow 55… 275 l / h
- thread connection. outside 3/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-10BQS Balancing and control valve
- with measuring points
- PN16, DN10
- flow 55… 275 l / h
- thread connection. outside 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-15BQS Balancing and control valve
- with measuring points
- PN16, DN15
- flow 90… 450 l / h
- thread connection. outside 3/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP228E-20BQS Balancing and control valve
- with measuring points
- PN16, DN20
- flow 180… 900 l / h
- thread connection. outside 1 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-25BQS Balancing and control valve
- with measuring points
- PN16, DN25
- flow 340… 1700 l / h
- thread connection. outside 1 1/4 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP229E-32BQS Balancing and control valve
- with measuring points
- PN16, DN32
- flow 640… 3200 l / h
- thread connection. outside 1 1/2 ″
- temperature range from -10˚C to 120˚C
- works with the MP130, MP131, MP300, SP90 actuators
VP220E-40CQS Balancing and control valve
- with measuring points
- PN16, DN40
- flow 3000… 7500 l / h
- thread connection. outside 2 ″
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP220E-50CQS Balancing and control valve
- with measuring points
- PN16, DN50
- flow 5000… 12500 l / h
- thread connection. outside 2 1/2 ″
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP220F-50CQS Balancing and control valve
- with measuring points
- PN16, DN50
- flow 5000… 12500 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP220F-65CQS Balancing and control valve
- with measuring points
- PN16, DN65
- flow 8000… 20000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP220F-80CQS Balancing and control valve
- with measuring points
- PN16, DN80
- flow 11200… 28000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP220F-100CQS Balancing and control valve
- with measuring points
- PN16, DN100
- flow 15200… 38000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP500C actuators
VP221F-125CQS Balancing and control valve
- with measuring points
- PN16, DN125
- flow 36000… 90000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP2000 actuators
VP221F-150CQS Balancing and control valve
- with measuring points
- PN16, DN150
- flow 58000… 145000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP2000 actuators
VP221F-125CQH Balancing and control valve
- with measuring points
- PN16, DN125
- flow 44000… 110000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP2000 actuators
VP221F-150CQH Balancing and control valve
- with measuring points
- PN16, DN150
- flow 76000… 190000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP2000 actuators
VP222F-200CQS Balancing and control valve
- with measuring points
- PN16, DN200
- flow 76000… 190000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP4000 actuators
VP222F-250CQS Balancing and control valve
- with measuring points
- PN16, DN250
- flow 112000… 280000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP4000 actuators
VP222F-200CQH Balancing and control valve
- with measuring points
- PN16, DN200
- flow 100000… 250000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP4000 actuators
VP222F-250CQH Balancing and control valve
- with measuring points
- PN16, DN250
- flow 148000… 370000 l / h
- flange connection
- temperature range from -10˚C to 120˚C
- works with MP4000 actuators

Schneider Electric SmartX PIBCV (VP22) balancing and control valves - a multifunctional device

Schneider Electric SmartX PIBCV (VP22) balancing and control valves are multifunctional devices with numerous applications in HVAC installations. They are composed of two components: a differential pressure regulator and a regulating valve.

Schneider Electric SmartX PIBCV (VP22) valves - important information

The series includes threaded and flanged models. Threaded versions are available in sizes from DN10 to DN50. Depending on the installation requirements, our offer includes models with or without measuring nozzles. Valves of this series can be controlled by actuators MP120, MP130, MP300-SR, MP500C and MP500C-SR from Schneider Electric.

In turn, the flanged models of the VP22 valves are offered in sizes from DN50 to DN250. All types are equipped with measuring points. They can be operated with the MP500C, MP500C-SR, MP2000, MP2000-SR and MP4000 Schneider Electric actuators.

Thanks to compliance with international standards for flow velocity in pipelines SmartX PIBCV valves od Schneider Electric guarantee reliable and precise work.

We cordially invite all people interested in investing in SmartX PIBCV (VP22) Schneider Electric balancing and control valves. Our employees will be happy to prepare an offer that meets your requirements and financial possibilities. The contact form is below.

All Schneider Electric SmartX PIBCV (VP22) series valves are equipped with a flow setpoint adjustment. They are designed to regulate the flow of the medium in cooling and heating devices. They are offered with actuators controlled by a whole range of control signals.

Features of Schneider Electric VP22 balancing and control valves:

  • Energy saving
    • The pressure independent operation of the control valve prevents overflow. Limiting the flow of the medium through the exchanger saves energy,
    • The overflow of the refrigerant limits the precision of the refrigerant temperature control.
    • Overflow of refrigerant beyond the design flow causes losses and ineffective heat transfer.
    • Correct and optimal flow rates guarantee the operational efficiency of the cooling or heating device.
  • No pressure fluctuations
    • Pressure-independent regulation ensures that pressure fluctuations downstream of the valve are eliminated, resulting in stable regulation.
    • Higher reliability due to fewer actuator cycles.
  • Lower pump costs
    • Reducing plant overflow lowers costs. The installation with the PICBV valve, compared to the traditional installation, requires the use of a pump with lower power and lower supply pressure.
  • Lower installation costs
    • Savings in investment costs by combining the functions of a control valve and flow limiter in one valve.
  •  Quick and efficient commissioning
    • The commissioning time of the installation is significantly reduced thanks to the simple and precise flow setting procedure which does not require the use of flow diagrams, calculations or the use of measuring devices