Grupa produktów została wycofana z produkcji.
Sugerowany zamiennik: Zawory do siłowników elektryczno-pneumatycznych GH-5000 JOHNSON CONTROLS
Tabela doboru produktu
Model (Excluding Voltage)* |
Flange Size |
Actuator Configuration |
Max. Operating Pressure (mbar) |
Opening Time (s) |
Stroke (mm) |
GH-5120-11_0 | DN40 | On-Off | 1,000 | ≤ 6.5 | 14 |
GH-5120-13_1 | On-Low-Off | ||||
GH-5129-14_1 | On-Low-Off + CPI | ||||
GH-5120-15_1 | Ignition On-Low-Off | ||||
GH-5129-16_0 | On-Off + CPI | ||||
GH-5129-16_0 | On-Off + CPI + MR | ||||
GH-5220-21_0 | DN50 | On-Off | 1,000 | ≤ 8 | 22 |
GH-5220-23_1 | On-Low-Off | ||||
GH-5229-24_1 | On-Low-Off + CPI | ||||
GH-5220-25_1 | Ignition On-Low-Off | ||||
GH-5229-26_0 | On-Off + CPI | ||||
GH-5229-29_0 | On-Off + CPI + MR | ||||
GH-5620-31_1 | DN65 | On-Off | 1,000 | ≤ 8 | 22 |
GH-5620-33_1 | On-Low-Off | ||||
GH-5629-34_1 | On-Low-Off + CPI | ||||
GH-5620-35_1 | Ignition On-Low-Off | ||||
GH-5629-36_1 | On-Off + CPI | ||||
GH-5629-39_1 | On-Off + CPI + MR | ||||
GH-5620-41_1 | DN80 | On-Off | 800 | ≤ 8 | 22 |
GH-5620-43_1 | On-Low-Off | ||||
GH-5629-44_1 | On-Low-Off + CPI | ||||
GH-5620-45_1 | Ignition On-Low-Off | ||||
GH-5629-46_1 | On-Off + CPI | ||||
GH-5629-49_1 | On-Off + CPI + MR | ||||
GH-5420-51_0 | DN100** | On-Off | 800 | ≤ 13 | 36 |
GH-5420-53_1 | On-Low-Off | ||||
GH-5429-54_1 | On-Low-Off + CPI | ||||
GH-5420-55_1 | Ignition On-Low-Off | ||||
GH-5429-56_0 | On-Off + CPI | ||||
GH-5429-59_0 | On-Off + CPI + MR | ||||
GH-5420-61_0 | DN125 | On-Off | 650 | ≤ 13 | 36 |
GH-5420-63_1 | On-Low-Off | ||||
GH-5429-64_1 | On-Low-Off + CPI | ||||
GH-5420-65_1 | Ignition On-Low-Off | ||||
GH-5429-66_0 | On-Off + CPI | ||||
GH-5429-69_0 | On-Off + CPI + MR | ||||
GH-5420-71_0 | DN150** | On-Off | 350 | ≤ 13 | 36 |
GH-5420-73_1 | On-Low-Off | ||||
GH-5429-74_1 | On-Low-Off + CPI | ||||
GH-542075_1 | Ignition On-Low-Off | ||||
GH-5429-76_0 | On-Off + CPI | ||||
GH-5429-79_0 | On-Off + CPI + MR | ||||
Continued on next page… |
* Complete Product Code Number by inserting a 1 or 3 for the blank number.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
**Material of valve body EN-GJL-250, DIN EN 1561
CPI = Closed Position Indicator
MR = with switch for manual restart
Model (Excluding Voltage)* |
Flange Size |
Actuator Configuration |
Max. Operating Pressure (mbar) |
Opening Time (s) |
Stroke (mm) |
GH-5720-51_0 | DN100** | On-Off | 800 | ≤ 13 | 36 |
GH-5720-53_1 | On-Low-Off | ||||
GH-5729-54_1 | On-Low-Off + CPI | ||||
GH-5720-55_1 | Ignition On-Low-Off | ||||
GH-5729-56_0 | On-Off + CPI | ||||
GH-5729-59_0 | On-Off + CPI + MR | ||||
GH-5720-61_0 | DN125** | On-Off | 650 | ≤ 13 | 36 |
GH-5720-63_1 | On-Low-Off | ||||
GH-5729-64_1 | On-Low-Off + CPI | ||||
GH-5720-65_1 | Ignition On-Low-Off | ||||
GH-5729-66_0 | On-Off + CPI | ||||
GH-5729-69_0 | On-Off + CPI + MR | ||||
GH-5720-71_0 | DN150** | On-Off | 350 | ≤ 13 | 36 |
GH-5720-73_1 | On-Low-Off | ||||
GH-5729-74_1 | On-Low-Off + CPI | ||||
GH-5720-75_1 | Ignition On-Low-Off | ||||
GH-5729-76_0 | On-Off + CPI | ||||
GH-5729-79_0 | On-Off + CPI + MR |
* Complete Product Code Number by inserting a 1 or 3 for the blank number.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
**Material of valve body EN-GJS-400, DIN EN 1563
CPI = Closed Position Indicator
MR = with switch for manual restart
Model (Excluding Voltage)* |
Threaded Size |
Actuator Configuration |
Max. Operating Pressure (mbar) |
Opening Time (s) |
Stroke (mm) |
GH-5110-21_0 | Rp¾ | On-Off | 1,000 | ≤ 6.5 | 14 |
GH-5110-23_1 | On-Low-Off | ||||
GH-5119-24_1 | On-Low-Off + CPI | ||||
GH-5110-25_1 | Ignition On-Low-Off | ||||
GH-5119-26_0 | On-Off + CPI | ||||
GH-5119-29_0 | On-Off + CPI + MR | ||||
GH-5110-31_0 | Rp1 | On-Off | 1,000 | ≤ 6.5 | 14 |
GH-5110-33_1 | On-Low-Off | ||||
GH-5119-34_1 | On-Low-Off + CPI | ||||
GH-5110-35_1 | Ignition On-Low-Off | ||||
GH-5119-36_0 | On-Off + CPI | ||||
GH-5119-39_0 | On-Off + CPI + MR | ||||
GH-5110-51_0 | Rp1½ | On-Off | 1,000 | ≤ 6.5 | 14 |
GH-5119-53_1 | On-Low-Off | ||||
GH-5119-54_1 | On-Low-Off + CPI | ||||
GH-5110-55_1 | Ignition On-Low-Off | ||||
GH-5119-56_0 | On-Off + CPI | ||||
GH-5119-59_0 | On-Off + CPI + MR | ||||
GH-5210-61_0 | Rp2 | On-Off | 1,000 | ≤8 | 22 |
GH-5210-63_1 | On-Low-Off | ||||
GH-5219-64_1 | On-Low-Off + CPI | ||||
GH-5210-65_1 | Ignition On-Low-Off | ||||
GH-5219-66_0 | On-Off + CPI | ||||
GH-5219-69_0 | On-Off + CPI + MR | ||||
GH-5610-71_1 | Rp2½ | On-Off | 1,000 | ≤8 | 22 |
GH-5610-73_1 | On-Low-Off | ||||
GH-5619-74_1 | On-Low-Off + CPI | ||||
GH-5610-75_1 | Ignition On-Low-Off | ||||
GH-5619-76_1 | On-Off + CPI | ||||
GH-5619-79_1 | On-Off + CPI + MR | ||||
GH-5610-81_1 | Rp3 | On-Off | 800 | ≤8 | 22 |
GH-5610-83_1 | On-Low-Off | ||||
GH-5619-84_1 | On-Low-Off + CPI | ||||
GH-5610-85_1 | Ignition On-Low-Off | ||||
GH-5619-86_1 | On-Off + CPI | ||||
GH-5619-89_1 | On-Off + CPI + MR |
* Complete Product Code Number by inserting a 1 or 3 for the blank number.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
1=230 VAC (50/60 Hz) models and 3=120 VAC (50/60 Hz) models.
CPI = Closed Position Indicator
MR = with switch for manual restart