The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching poin...
The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes.
Tabela doboru produktu
Type | Opis |
TAM022 | Capillary Thermostat -20…+20 °C (IP54) SIL 2 |
TAM022-206 | Capillary Thermostat -20…+20 °C (IP54) SIL 2 |
TAM022-206-S | Capillary Thermostat -20…+20 °C (IP54) SIL 2 |
TAM022-301 | Capillary Thermostat -20…+20 °C, terminal connection (IP65) SIL 2 |
TAM022-301-S | Capillary Thermostat -20…+20 °C, terminal connection (IP65) SIL 2 |
TAM022-306 | Capillary Thermostat (IP65) SIL 2 |
TAM022-306-S | Capillary Thermostat (IP65) SIL 2 |
TAM022-351 | Capillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM022-351-S | Capillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM022-513 | Capillary Thermostat -20…+20°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM022-513-S | Capillary Thermostat, Ex-i, gold plated contact (IP65) SIL2 |
TAM022-S | Capillary Thermostat (IP54) SIL 2 |
TAM150 | Capillary Thermostat (IP54) SIL 2 |
TAM150-205 | Capillary Thermostat (IP54) SIL 2 |
TAM150-205-S | Capillary Thermostat (IP54) SIL 2 |
TAM150-206 | Capillary Thermostat (IP54) SIL 2 |
TAM150-206-S | Capillary Thermostat (IP54) SIL 2 |
TAM150-213 | Capillary Thermostatgold plated contact (IP54) SIL 2 |
TAM150-213-S | Capillary Thermostatgold plated contact (IP54) SIL 2 |
TAM150-301 | Capillary Thermostat, terminal connection (IP65) SIL 2 |
TAM150-301-S | Capillary Thermostat, terminal connection (IP65) SIL 2 |
TAM150-305 | Capillary Thermostat (IP65) SIL 2 |
TAM150-305-S | Capillary Thermostat (IP65) SIL 2 |
TAM150-351 | Capillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM150-351-S | Capillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM150-513 | Capillary Thermostat +10…+50°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM150-513-S | Capillary Thermostat +10…+50°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM150-S | Capillary Thermostat (IP54) SIL 2 |
TAM490 | Capillary Thermostat (IP54) SIL 2 |
TAM490-205 | Capillary Thermostat (IP54) SIL 2 |
TAM490-205-S | Capillary Thermostat (IP54) SIL 2 |
TAM490-213 | Capillary Thermostatgold plated contact (IP54) SIL 2 |
TAM490-213-S | Capillary Thermostatgold plated contact (IP54) SIL 2 |
TAM490-301 | Capillary Thermostat, terminal connection (IP65) SIL 2 |
TAM490-301-S | Capillary Thermostat, terminal connection (IP65) SIL 2 |
TAM490-305 | Capillary Thermostat (IP65) SIL 2 |
TAM490-305-S | Capillary Thermostat (IP65) SIL 2 |
TAM490-351 | Capillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM490-351-S | Cpillary Thermostat, terminal connection, chemical version (IP65) SIL 2 |
TAM490-513 | Capillary Thermostat +40…+90°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM490-513-S | Capillary Thermostat +40…+90°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM490-S | Capillary Thermostat (IP54) SIL 2 |
TAM813 | Capillary Thermostat +80…+130°C (IP54) SIL 2 |
TAM813-205 | Capillary Thermostat +80…+130°C (IP54) SIL 2 |
TAM813-205-S | Capillary Thermostat +80…+130°C (IP54) SIL 2 |
TAM813-301 | Capillary Thermostat +80…+130°C, terminal connection (IP65) SIL 2 |
TAM813-301-S | Capillary Thermostat +80…+130°C, terminal connection (IP65) SIL 2 |
TAM813-305 | Capillary Thermostat +80…+130°C, terminal connection (IP65) SIL 2 |
TAM813-305-S | Capillary Thermostat +80…+130°C, terminal connection (IP65) SIL 2 |
TAM813-313 | Capillary Thermostat +80…+130°C, gold plated contacts, terminal connection (IP65) SIL 2 |
TAM813-313-S | Capillary Thermostat +80…+130°C, gold plated contacts, terminal connection (IP65) SIL 2 |
TAM813-351 | Capillary Thermostat +80…+130°C, terminal connection, chemical version (IP65) SIL 2 |
TAM813-351-S | Capillary Thermostat +80…+130°C, terminal connection, chemical version (IP65) SIL 2 |
TAM813-513 | Capillary Thermostat +80…+130°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM813-513-S | Capillary Thermostat +80…+130°C, Ex-i, gold plated contact (IP65) SIL2 |
TAM813-563 | Capillary Thermostat 1.5m, +80…+130°C, Ex-i, gold plated contact, chemical version (IP65) SIL2 |
TAM813-563-S | Capillary Thermostat +80…+130°C, Ex-i, gold plated contact, chemical version (IP65) SIL2 |
TAM813-S | Capillary Thermostat +80…+130°C (IP54) SIL 2 |
• 213: gold-plated contacts, switching capacity: max. 24 VDC,100 mA, min. 5 VDC, 2 mA. And others not available with adjustable switching difference.
• 301: terminal connection housing, IP65
• 351: protection class IP65 and switching housing with surface protection (chemical version)
• 513: gold-plated contacts, IP65, capacity: max. 24 VDC, 100 mA, min. 5 VDC, 2 mA, degree of protection Ex-i