The M7410E Honeywell actuators are used in fan coil units, suction units, small superheaters and coolers where they control the operation of the V5822, V5823, V5832, V5833 and V5825B line valves ...
The M7410E Honeywell actuators are used in fan coil units, suction units, small superheaters and coolers where they control the V5822, V5823, V5832, V5833 and V5825B Honeywell line valves. They are intended for use in installations with hot or cold water. These devices are fully compatible with all controllers with 0… 10V or 2… 10V output signal.
Product selection table
Model | Types | Manual operations | Stem strength | Connector S1 | Connector S2 | Housing type |
M7410E1002
M7410E1028 |
standard | provided by the valve handwheel | 180 N
300 N |
—
— |
—
— |
B
B |
M7410E2026
M7410E2034 |
with control manual |
integrated | 180 N
300 N |
—
— |
—
— |
C
C |
M7410E4022
M7410E4030 |
with manual control and switches | integrated | 180 N
300 N |
x
x |
x
x |
C
C |
M7410E5001 | standard | integrated | 90 N | — | — | B |
Special versions: other cable length, length = 3m / 5m / 10m (on special request) |
Accessories
Model | Description |
0903403 | adapter for valves series V5077B / V5078B |
The M7410E Honeywell actuator is designed for use in locations with limited installation space and in applications that require minimal power consumption. High-quality microprocessor positioner ensures precise control.
Long and reliable operation is guaranteed by the absence of a mechanical feedback potentiometer and the absence of mechanical limit switches. The automatic synchronization function determines a self-setting closing point. Based on a 150 second duty cycle, the valve positioner and flow controller is highly accurate. All types of switches can be operated manually. The actuator housing looks attractive, it is also solidly constructed. A special version with auxiliary switches is available.
The individual models differ in the strength of the spindle and the type of housing. For the M7410E1028 Honeywell, the mandrel force is 300N.
- Adjust the output pressure with the adjustment knob
- The setting spring is outside the flow area
- Compact design
- Internal thread
- Light weight
- Short installation length
- Inlet Pressure Compensation - Changes in inlet pressure have no effect on the outlet pressure
- The design complies with the Pressure Equipment Directive 97/23 / EC, ref. CE 0035
- Reliable and sure
We invite you to familiarize yourself with the full offer of our store. Among other things, we offer a wide selection
temperature sensors, pressure sensors and pressure switches many renowned international brands. This group includes such concerns as Johnson Controls, Belimo and Siemens.
120 seconds at 60Hz
180N (for valves DN 15 ... 20)
300N (for valves DN 25 ... 40 and V5825B)