Astra Automatyka > Produkty > Sensors and transducers > Pressure > Differential pressure switch for liquid and gas DDCM Honeywell / FEMA
Differential pressure switch for liquid and gas DDCM Honeywell / FEMA

FEMA / Honeywell differential pressure monitors DDCM are suitable for monitoring and controlling differential pressures, flow monitoring and automatic control of filter sys-tems. A double chamber syst...

FEMA / Honeywell differential pressure monitors DDCM are suitable for monitoring and controlling differential pressures, flow monitoring and automatic control of filter sys-tems. A double chamber system with stainless steel bellows or Perbunan diaphragm detects the difference between the two applied pressures.


Product comparison
Type Pressure adjustment
range
Switching
differential
Max. pressure
DDCM252 4…25 mbar 2 mbar 0,5 bar
DDCM252-205 4…25 mbar 2 mbar 0,5 bar
DDCM252-213 4…25 mbar 2 mbar 0,5 bar
DDCM252-301 4…25 mbar 2 mbar 0,5 bar
DDCM252-313 4…25 mbar 2 mbar 0,5 bar
DDCM252-351 4…25 mbar 2 mbar 0,5 bar
DDCM252-513 4…25 mbar 2 mbar 0,5 bar
DDCM252-563 4…25 mbar 2 mbar 0,5 bar
DDCM252-574 4…25 mbar 2 mbar 0,5 bar
DDCM252-576 4…25 mbar 2 mbar 0,5 bar
DDCM662 10…60 mbar 15 mbar 1,5 bar
DDCM662-213 10…60 mbar 15 mbar 1,5 bar
DDCM662-351 10…60 mbar 15 mbar 1,5 bar
DDCM662-363 10…60 mbar 15 mbar 1,5 bar
DDCM662-513 10…60 mbar 15 mbar 1,5 bar
DDCM6002 100…600 mbar 35 mbar 3 bar
DDCM6002-213 100…600 mbar 35 mbar 3 bar
DDCM6002-301 100…600 mbar 35 mbar 3 bar
DDCM014 -0,1…0,4 bar 0,15 bar 15 bar
DDCM014-211 -0,1…0,4 bar 0,15 bar 15 bar
DDCM014-313 -0,1…0,4 bar 0,15 bar 15 bar
DDCM014-351 -0,1…0,4 bar 0,15 bar 15 bar
DDCM014-513 -0,1…0,4 bar 0,15 bar 15 bar
DDCM1 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-213 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-301 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-313 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-351 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-513 0,2…1,6 bar 0,13 bar 15 bar
DDCM1-563 0,2…1,6 bar 0,13 bar 15 bar
DDCM4 1…4 bar 0,20 bar 25 bar
DDCM4-513 1…4 bar 0,20 bar 25 bar
DDCM6 0,5…6 bar 0,20 bar 15 bar
DDCM6-213 0,5…6 bar 0,20 bar 15 bar
DDCM6-301 0,5…6 bar 0,20 bar 15 bar
DDCM6-313 0,5…6 bar 0,20 bar 15 bar
DDCM6-351 0,5…6 bar 0,20 bar 15 bar
DDCM6-363 0,5…6 bar 0,20 bar 15 bar
DDCM6-513 0,5…6 bar 0,20 bar 15 bar
DDCM16 3…16 bar 0,60 bar 25 bar
DDCM16-213 3…16 bar 0,60 bar 25 bar
DDCM16-313 3…16 bar 0,60 bar 25 bar
DDCM16-513 3…16 bar 0,60 bar 25 bar
DDCM1602 20…160 mbar 20 mbar 3 bar
DDCM1602-213 20…160 mbar 20 mbar 3 bar
DDCM1602-301 20…160 mbar 20 mbar 3 bar
DDCM1602-351 20…160 mbar 20 mbar 3 bar
DDCM1602-513 20…160 mbar 20 mbar 3 bar
DDCM1602-576 20…160 mbar 20 mbar 3 bar
DDCM1602-S 20…160 mbar 20 mbar 3 bar

Add the type numbers below to the listed type numbers for extra functionality as described:
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i

The desired switching pressure is continuously adjustable within the ranges mentioned in the product summary. All differential pressure monitors can also be used in the vacuum range. The switching differential is not adjustable.

The DDCM Honeywell / FEMA series are calibrated for falling pressure. This means that the adjustable pressure on the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount of the switching differential.